| Date de lancement | Marque / Modèle | Problème | Correctif | Période de production | Réf. constructeur | Véhicules |
|---|---|---|---|---|---|---|
| 2005-03-01 |
IVECO - EUROTECH
EUROTECH
|
POSSIBILITY THAT CONTAMINATED AIR CAN BE DRAWN INTO INTAKE SYSTEM | Recall affected vehicles and fit a protective grille over the air intake pipe | 1998-04-22 → 2003-07-03 | RCV06 | 1747 |
| 2003-06-02 |
IVECO - EUROTECH
EUROTECH
|
INSECURITY OF CAB TOP AND SIDE SPOILER BRACKET | Check the glued mountings on the top and side spoiler with a spring balance to 40-50 kg. If the bond fails reglue the brackets as per the manufacturer's instructions. | - → - | W58 | 3 |
| 2003-05-01 |
IVECO - EUROTECH
EUROTECH
|
FRONT BRAKE HOSE CONNECTIONS MAY BE INCORRECTLY FITTED | Check brake hose connections for tightness and leaks. Rectify where necessary. | - → - | W14 | 8 |
| 2003-05-01 |
IVECO - EUROTECH
EUROTECH
|
STEERING COLUMN SHAFT MAY BE INCORRECT LENGTH | Check the length of the column shaft and replace where necessary. | - → - | W52 | 8 |
| 2003-01-27 |
IVECO - EUROTECH
EUROTECH
|
POSSIBILE AIR LOSS FROM BRAKE SYSTEM | To prevent corrosion in the pressure regulator APU a new rubber diaphragm will be fitted. | 1998-04-17 → 2002-06-27 | W87 | 1872 |
| 2000-04-01 |
IVECO - EUROTECH
EUROTECH
|
DRIVERS CAB MAY COLLAPSE WHEN TILTED | Recall affected vehicles and replace the support bracket with a modified type. | 1998-01-01 → 2000-12-31 | W21 | 21 |
| 1999-09-01 |
IVECO - EUROTECH
EUROTECH
|
REAR WHEELS MAY LOCK | Recall potentially affected vehicles and remove the automatic engine braking control switch. | 1998-12-01 → 1999-06-30 | 6 | |
| 1998-02-12 |
IVECO - EUROTECH
EUROTECH
|
POSSIBLE INADVERTENT APPLICATION OF PARKING BRAKE | The affected vehicles are being recalled to be inspected for the make of parking brake valve fitted. A securing clamp will be fitted to all the affected units to prevent displacement of the ball. | - → - | 4332 | |
| 1994-10-27 |
IVECO - EUROTECH
EUROTECH
|
SERVICE BRAKE CONTROL VALVE | Recall the defective vehicles to check the subject valve. Defective valves will be replaced with a new unit. | - → - | 44 |